[343]: data by Julio Fernandez Mendy MD, Buenos Aires, Argentina
[393]: data by Dres Becker, Cordero, Maruniak. SA60AT - Model SA60AT AcrySof Single-Piece Posterior Chamber Intraocular Lenses, UV-Absorbing, Acrylic Foldable - Alcon AU00T0 AcrySof IQ Ashperic Posterior Chamber with UltraSert IOL IFU [32]: data by Dr.V.Hessemer, Darmstadt, Germany
(*): A-const taken from: Mohr A, Hengerer F, Eckardt C: Retropupillare Fixation der Irisklauenlinse bei Aphakie. [360]: data by Dr. Claudio Carbonara, Roma, Italy
[209]: data by Dr.K.Meyer-Hamme, Ludwigsburg, Germany
AMO Sensar 1-piece AAB00 A=118.4 a0= -1.004 a1=0.182 a2=0.232 pACD=5.56 sf=1.78 A=119.0 A=119.3 415 [316],[18],[368],[390],[392]
AMO PS60 ANB A=116.7 a0=1.15 a1=0.40 a2=0.10 pACD=5.46 sf=1.65 A=118.7 A=118.9 18 [2]
Technoko TA625 A=118.0 a0=1.17 a1=0.40 a2=0.10 pACD=5.32 sf=1.59 A=118.7 A=119.1 40 [54]
Zarracom Focusforce Ultraflex UF60125 A=118.4 a0=1.58 a1=0.40 a2=0.10 pACD=5.75 sf=1.99 A=119.3 A=119.7 48 [347]
[33]: data by D.Uthoff, MD, Kiel, Germany
[339]: data by Bonnie J Brooks MD, Brunswick GA, USA
Posterior capsule opacification after implantation of a hydrophilic or a hydrophobic acrylic intraocular lens: one-year follow-up. AMO SI30 NB A=117.4 a0=1.23 a1=0.40 a2=0.10 pACD=5.34 sf=1.58 A=118.5 A=118.6 34 [15]
[271]: data by Dr.G.Sauder, Stuttgart, Germany
Suggested A-Constant: 118.7 Special Feature: Posterior Aspheric Surface. [81]: data by Dr.T.Laube, Duesseldorf, Germany
[137]: data by Dr.L.Banyai, Leonberg, Germany
2019;45:1490-1497. [165]: data by Dr.R.Friedrich, Meiningen, Germany
[284]: data by Prof.Dr.G.Alessio, Bari,Italy
[50]: data by Dr.L.Henke, Gummersbach, Germany
[268]: data by Dr. F.Kesteloot, Kortrijk, Belgium
J Cataract Refract Surg. W2O CareFlex II A=118.7 a0= 1.32 a1=0.40 a2=0.10 pACD=5.52 sf=1.75 A=118.9 A=119.2 146 [91],[142]
[100]: data by K.Bump, New York, NY, USA
Last Revision: Oct 31, 2016 WH, (*): A-const taken from: Mohr A, Hengerer F, Eckardt C: Retropupillare Fixation der Irisklauenlinse bei Aphakie. [143]: data by Dr.K.Petermeier, Tbingen, Germany
[136]: data by Dr.J.Blazek, Pardubice, Czech Republic
[77]: data by Dr.Baha Toygar, Istanbul, Turkey
Keith A.Gross MD, New Zealand,
[352]: data by Dr. Dale Pilkinton, Nashville, TN, USA
[130]: data by D.L.Cooke MD, St.Joseph, MI, USA
[144]: data by Dr.W.Schindler, Eichsttt, Germany
[58]: data by R.Kaufer, MD, Argentina
biometry and partial coherence interferometry for IOL calculation according to
[97]: data by Asim Piracha, MD, West Mifflin, PA, USA
[355]: data by Dres. United Kingdom - English, Americas
[384]: data by Prof. JOO Choun-Ki, Seaoul, South Korea
ZEISS Acri.Lyc 45S A=118.2 a0=1.20 a1=0.40 a2=0.10 pACD=5.41 sf=1.64 A=118.7 A=119.1 158 [214],[215]
The SA30AL and SA60AT IOLs both have a manufacturer-identified A-constant of 118.4. Clin Ophthalmol. [90]: data by Dr.R.Wiedemann, Leipzig, Germany
ZEISS AT LISA 801 (Acri.LISA 376D) A=117.7 a0=0.82 a1=0.40 a2=0.10 pACD=5.06 sf=1.26 A=118.1 A=118.0 48 [231]
Domilens Flex65L discontinued A=118.4 a0=1.45 a1=0.40 a2=0.10 pACD=5.68 sf=1.88 A=118.9 A=118.9 50 [2],[18]
Since they reflect the special hardware and processing conditions of the instrument type applied for data acquisition,
Russia, Asia Pacific [212]: data by Dr.A.Ilkhani, Singen, Germany
[40]: data by Dr.Jeffrey Sher, Hamilton, Ontario, Canada
(balanced salt solution enriched with bicarbonate, dextrose, and glutathione), CELLUGEL Ophthalmic Viscosurgical Device (OVD), CLEAR CARE Cleaning and Disinfecting Solution, CLEAR CARE Plus Cleaning and Disinfecting Solution with HydraGlyde, (cyclopentolate hydrochloride ophthalmic solution, USP), (cyclopentolate hydrochloride and phenylephrine hydrochloride ophthalmic solution), DAILIES AquaComfort Plus Contact Lenses, DAILIES AquaComfort Plus Multifocal (nelfilcon A) One-Day Contact Lenses, DAILIES AquaComfort Plus Toric Contact Lenses, DAILIES COLORS (nelfilcon A) Soft Contact Lenses, DAILIES TOTAL1 Water Gradient Contact Lenses, DISCOVISC Ophthalmic Viscosurgical Device (OVD), (sodium chondroitin sulfate sodium hyaluronate), EYESCRUB Sterile Eye Makeup Remover and Eyelid Cleansing Pads, FOCUS DAILIES Progressives Contact Lenses, ICAPS Eye Vitamin - AREDS Formula - Softgel, ICAPS Eye Vitamin - AREDS Formula - Coated Tablets, ICAPS Eye Vitamin - Lutein and Zeaxanthin, ICAPS Eye Vitamin & Mineral Supplement - Multivitamin, ISOPTO Atropine (atropine sulfate ophthalmic solution) 1% for topical ophthalmic use, ISPAN Perfluoropropane C3F8 - For use with CONSTELLATION Vision System. [145]: data by Dr.T.Haldimann, Bern, Schweiz
[167]: data by Dr.D.Rettenmaier, Schramberg, Germany
[237]: data by Dr.Matteo Piovella, Monza, Italy
Pseudophakic dysphotopsia was diagnosed in 26 eyes of 18 patients (1% of 2630 cases), with 1 patient requiring an IOL exchange. [38]: data by Dr.Michaela Mees, Sulzbach, Germany
All lens power below 6 diopter are available in meniscus design on the Acrysof platform (MA60MA). [368]: data by Dr. Martin Bechmann, Mnchen, Germany
The .gov means its official. [29]: data by Dr.D.Johann, Koblenz, Germany
[7]: based on data by G.Gerten, MD, Cologne, Germany
The crop factor is used by experienced photographers, who want to know the field of view of a lens on a digital camera as compared to a lens on an analog 35mm camera, which they have been using for years. Ophtec PC 620 Luna - discontinued A=119.0 a0=1.71 a1=0.40 a2=0.10 pACD=5.91 sf=2.13 A=119.6 A=120.0 52 [247]
Santen X-70 (Japan) A=118.9 a0=1.86 a1=0.40 a2=0.10 pACD=6.05 sf=2.24 A=119.6 A=119.9 78 [251]
[371]: data by Dr. Harald Freydell, Medellin, Colombia
[106]: data by Dr.E.Becker, Oranienburg, Germany
[382]: data by Dr. KIM Joon Hyun, Seoul, South Korea
In a review of 2630 consecutive cases operated on from January 2000 through July 2001, ease of IOL insertion and integrity of the haptic architecture were evaluated in a prospective fashion at implantation.
Tel: +004 111 1111 111 Website, Universal lens resource for Opthalmologists. By continuing to browse the site you are agreeing to accept our use of cookies. [343]: data by Julio Fernandez Mendy MD, Buenos Aires, Argentina
[232]: data by Dr.H.J.Gross, Margate, NJ, USA
[1]: HAIGIS W, LEGE B, MILLER N, SCHNEIDER B: Comparison of immersion ultrasound
[2]: results based on data by
[104]: data by Prof.Dr.V.Seiberth, Germany
[98]: data by A.Rivett, Adelaide, Australia
For relations between optimized IOL constants for different IOL formulas click here.
[245]: data by Dr.Klaus Ellendorff, Lneburg, Germany
[3]: based on data by J.L.Parisi MD, Clemson SC, USA and Harvey K.Minatoya MD, Honolulu, HI, USA
The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies.
[270]: data by Dr.A.Rosa Almeida, Ipatinga, Brazil
[261]: data by Dr. E.Mertens, Eersel, The Netherlands
[372]: data by Dr. W. Wehner, Nrnberg, Germany
[327]: data by Mr. Say Aun Quah and Mrs. C.Gore, Manchester, UK
Omni LBHY32UVASP A=119.0 a0=1.70 a1=0.40 a2=0.10 pACD=5.88 sf=2.14 A=119.6 A=120.0 49 [349]
[218]: data by Dr.Jens Klett, Herne, Germany
ZEISS CT ASPHINA 404 (Acri.Lyc 44LC) A=118.0 a0=0.126 a1=0.025 a2=0.190 pACD=5.25 sf=1.49 A=118.5 A=118.7 237 [216]
[58]: data by R.Kaufer, MD, Argentina
[286]: data by Dr. Martin Drner, Bocholt, Germany
[247]: data by Dr.Franc Salamun, Nova Gorica, Slovenia
Alcon SN60WF (Japan) A=118.7 a0= -1.268 a1=0.342 a2=0.233 pACD=5.79 sf=1.95 A=119.1 A=119.4 202 [41]
[6]: based on data by different surgeons from Eye Clinic Kln-Merheim, Germany
[21]: data by A.Koletzko,MD, Moers, Germany
2015 Jun;253(6):973-7. doi: 10.1007/s00417-015-3029-8. Hoya AF-1 FY-60AD Hoya iSert PY-60AD (+) A=118.4 a0= -0.093 a1= -0.023 a2=0.208 pACD=5.30 sf=1.54 A=118.6 A=118.8 254 [43],[157],[81],[103],[172],[266]
The SRK T formula is a third generation formula, described in 1990 by John Retzlaff, Kraff and Sanders [6]. The ratio of the focal length of a digital camera lens to a 35mm still camera lens. Maxwell A, Suryakumar R. Long-term effectiveness and safety of a three-piece acrylic hydrophobic intraocular lens modified with hydroxyethyl-methacrylate: an open-label, 3-year follow-up study. Unhappy? [232]: data by Dr.H.J.Gross, Margate, NJ, USA
[54]: data by Dr.A.Gross, Burghausen, Germany
It therefore has a 1:1 ratio with the formulas recommended IOL power outcome. [147]: data by Dr.K.Weber, Ludwigshafen, Germany
1stQ Basis Z A=118.0 a0=0.325 a1=0.255 a2=0.141 pACD=5.01 sf=1.25 A=118.1 A=118.3 672 [49],[223],[224],[84],[33],[245],[122],[246],[271],[272],[286],[350]
[17]: data by J.Brndle, MD, Fssen, Germany
C.Wehner MD(Bremervrde, Germany),
[320]: data by Dr.Mjn Carter, Bloemfontein, South Africa
LENSES AcrySof SA60 AT/ SN60 AT White (MA) or Yellow spherical (SN) with aspheric Optic One piece Hydrophobic IOL, extended dioptric Range to +40.0 D. Category: LENSES Brand: ALCON Additional information [66]: data by Dr.S.Schler, Minden, Germany
[4]: based on data by Llyod Taustine MD, New Albany IN, USA
[376]: data by Mr. Mark Cahill, Dublin, Ireland
[161]: data by Dr.K.Schneider, Mnchengladbach, Germany
So, an increase of 0.50 in the lens constant will produce an IOL power outcome prediction that is also 0.50 D greater. Oshika T, Fujita Y, Inamura M, Miyata K. Mid-term and long-term clinical assessments of a new 1-piece hydrophobic acrylic IOL with hydroxyethylmeth-acrylate. [123]: data by Dr.J.Bosche, Diepholz, Germany
[127]: data by H.Geggle MD,Seattle, WA, USA
ALCAINE (proparacaine hydrochloride ophthalmic solution, USP) 0.5% Product Information Anterior Chamber Lenses - KELMAN MULTIFLEX III PMMA Single-Piece IOL MODEL MTA2UO-7UO Product Information BETADINE 5% Ophthalmic Prep Solution (povidone-iodine ophthalmic solution) BETADINE is a registered trademark of The Purdue Frederick Company. (****): results based on highly myopic patients (mean axial lengths: 29.56 +/- 1.51 mm
Colombia [278]: data by Jason Jacobs, MD, Denver, CO, USA
Bausch&Lomb Akreos FIT A=118.0 a0=0.78 a1=0.40 a2=0.10 pACD=5.02 sf=1.26 A=118.1 A=118.3 71 [24]
Ocular Implants, Lens Implants, and Devices More. Constants for IOLs characterized by '(Japan)'are based on results for Japanese eyes, which tend to be somewhat longer
[217]: data by Mr.S.Beatty, Waterford, Ireland
Alcon Toric SN6AT(3-5) (Japan)A=119.0 a0= 1.78 a1=0.40 a2=0.10 pACD=5.91 sf=2.08 A=119.3 A=119.6 77 [41]
[277]: data by Dr.M.Winter, Bremen, Germany
[288]: data by Aurolab, India
Minimum quantity for "Alcon SA60AT Intraocular Lens, UV, Power 18.5D, Length 13mm, Optic 6mm (x)" is 1.
[110]: data by Dr.H.Wenkel, Coburg, Germany
Rayner C-Flex 570 C A=118.0 a0=1.27 a1=0.40 a2=0.10 pACD=5.46 sf=1.68 A=118.8 A=119.1 149 [52],[73],[38]
[10]: data by R.Walter-Fincke, MD, and W.Bachmann, MD, Aschaffenburg, Germany
[393]: data by Dres Becker, Cordero, Maruniak. [269]: data by Augenzentrum Maus, Kln, Germany
[392]: data by Dr. M. Gamringer-Kroher, Weiden, Deutschland
[11]: data by Dr.B.Hrster and Dr.Thamaz, Erkelenz, Germany
[322]: data by P.Roholt MD, Canton OH, USA
[227]: data by PD Dr.J.Weindler, Esslingen, Germany
A prospective, randomised comparison of single and three piece acrylic foldable intraocular lenses. [153]: data by Dr.Bouchout, France
[400]: data by Prof. Dr. R. Menapace, Vienna, Austria
AMO Tecnis ZMA00 A=119.1 a0= -1.750 a1=0.242 a2=0.266 pACD=5.80 sf=2.06 A=119.5 A=120.0 205 [78],[243]
[111]: data by Dr.A.Schweiker, Pforzheim, Germany
ZEISS CT SPHERIS 204 (Acri.Lyc 44S) A=118.0 a0=0.93 a1=0.40 a2=0.10 pACD=5.16 sf=1.40 A=118.3 A=118.5 177 [16],[18],[207],[230],[404]
[61]: data by R.Donoso, Chile
[289]: data by HSK Wiesbaden, Germany
VSY Acriva UD Reviol MF 613 A=118.0 a0=0.65 a1=0.40 a2=0.10 pACD=4.93 sf=1.20 A=118.1 A=118.3 48 [255]
Alcon Panoptix TFNT00 A=119.1 a0=1.39 a1=0.40 a2=0.10 pACD=5.63 sf=1.83 A=119.1 A=119.3 26 [395]
HumanOptics MC611MI discontinued A=118.3 a0=1.59 a1=0.40 a2=0.10 pACD=5.85 sf=2.08 A=119.4 A=119.8 66 [70]
Would you like email updates of new search results? Das KK, Werner L, Collins S, Hong X. [14]: data by P.Ursin, Nordhausen, Germany
Hanita B-lens A=118.2 a0=1.01 a1=0.40 a2=0.10 pACD=5.26 sf=1.52 A=118.6 A=118.8 52 [136]
[379]: data by Dr .PARK Young Jeung, Daegu, South Korea
[228]: data by Dr.R.v.Horenbeeck, Antwerpen, Belgium
[12]: data by E.Frieling, MD,Mnchen, Germany
The lens has a biconvex optic with supporting haptics. Rayner Centerflex 570 H A=118.0 a0=1.04 a1=0.40 a2=0.10 pACD=5.22 sf=1.45 A=118.4 A=118.7 118 [38],[52]
Ocular Implants, Lens Implants, and Devices More. A=116.8 (*) a0= -0.25 a1=0.40 a2=0.10 pACD=4.34 sf=0.54 A=116.9 A=116.8 20 [52],[64]
K.Lucke MD(Bremen, Germany),
Domilens Nidek NS-60YG Aktis SP y A=118.4 a0=1.61 a1=0.40 a2=0.10 pACD=5.81 sf=2.03 A=119.3 A=119.7 127 [264],[226],[313]
Surv Ophthalmol. [401]: data by Dr. F. Kretz, Rheine, Grmany
Hoya iSert Micro 251 (Japan) A=118.4 a0=0.570 a1=0.197 a2=0.163 pACD=5.54 sf=1.72 A=118.8 A=119.0 249 [41]
Given a normal postoperative topical steroid regimen, there were no cases of substantially increased or prolonged iritis. [102]: data by Fritz Ruck GmbH, Eschweiler, Germany
[126]: data by S.Suh MD, Westerville, OH, USA
Domilens Nex-Load Preloaded A=119.2 a0=1.73 a1=0.40 a2=0.10 pACD=5.87 sf=2.11 A=119.5 A=120.0 98 [222]
[114]: data by surgeons of Moorfields Eye Hospital, London, UK
Optic glistenings were observed in 11 (11%) of 100 SA30AL cases at a mean follow-up of 8 months. Alcon AcrySof MA60BM A=118.9 a0=1.443 a1=0.077 a2=0.163 pACD=6.08 sf=2.33 A=119.8 A=120.4 271 [2],[10],[18]
[351]: data by Prof.Rakic, Dr.van Cauwenberge, Liege, Belgium
Constants to download: Biometer: all Haag-Streit Lenstar Haag-Streit Lenstar LS900 Heidelberg E. Anterion Nidek AL-Scan Oculus Pentacam Okulix Tomey OA-2000 Topcon Aladdin Zeiss IOLMaster Zeiss IOLMaster 500 Zeiss IOLMaster 700 Ziemer GALILEI G6 Moss Vision Optiflex MO/F-022 A=118.5 a0=1.37 a1=0.40 a2=0.10 pACD=5.61 sf=1.85 A=119.1 A=119.5 49 [369]
The lens consists of a high refractive index soft acrylic material capable of being folded prior to insertion. [370]: data by Mr. Azfar W. Chohan, Isle of Man
[151]: data by Dr.Lebrun, France
[329]: data by AMO Germany GmbH
[202]: data by M.Franke, Kirchberg, Germany
Moss Vision Optiflex MO/F-023 A=118.5 a0=1.42 a1=0.40 a2=0.10 pACD=5.60 sf=1.82 A=119.0 A=119.4 49 [369]
(**): results based on predominantly myopic patients (mean axial length: 24.48 +/- 1.87 mm)
Constants are given without any legal responsibility ! Polytech Polylens AS66/AS66-Y A=118.2 a0= 0.939 a1=0.250 a2=0.133 pACD=5.39 sf=1.60 A=118.6 A=118.9 283 [273],[282],[287]
In addition, the Clareon Aspheric Toric IOL is indicated to correct pre-existing corneal astigmatism.WARNINGS/PRECAUTIONS: The Clareon IOL is intended for implantation in the capsular bag only. [294]: data by Prof. Mark Packer MD, Eugene, OR, USA
[104]: data by Prof.Dr.V.Seiberth, Germany
Alcon SA60AT AcrySof Single-Piece Acrylic Foldable IOL (x) IOL (Model SA60AT). [293]: data by Tomasz Trzos, Grlitz, Germany
2005 Nov;89(11):1453-7. doi: 10.1136/bjo.2005.067405. Staar AQ 2003V A=118.5 a0=1.53 a1=0.40 a2=0.10 pACD=5.73 sf=1.96 A=119.2 A=119.6 65 [54]
If optimized lens constants are not available, these should be considered as only a starting point. [9]: based on data by M.Kchle, MD, Erlangen, Germany
Argentina J Cataract Refract Surg. [214]: data by Dr.R.Beck, Rostock, Germany
[95]; data by Dr.R.Wertheimer,Mnchen, Germany
[404]: data by Dres.
Oculentis L-403 A=118.0 a0= 1.02 a1=0.40 a2=0.10 pACD=5.16 sf=1.41 A=118.4 A=118.7 14 [106]
[346]: data by Dr. Rudolf Sieben, Aachen, Germany
ZEISS AT TORBI 709 MP A=118.3 a0=1.13 a1=0.40 a2=0.10 pACD=5.37 sf=1.59 A=118.5 A=118.3 48 [372]
[329]: data by AMO Germany GmbH
[370]: data by Mr. Azfar W. Chohan, Isle of Man
[231]: data by Dr.A.Bach, Schwerin, Germany
[43]: data by Dr. D. de Ortueta, MD, Recklinghausen, Germany
[164]: data by Dr.U.Berens, Karlsruhe, Germany
AMO Tecnis Z9002 A=118.7 a0= -1.201 a1=0.102 a2=0.246 pACD=5.46 sf=1.67 A=118.8 A=119.0 1275 [109],[139],[140],[19],[103],[104],[72],[98],[232],[234],[239]
Polytech Polylens AS62 A=118.2 a0= -1.527 a1=0.152 a2=0.237 pACD=5.04 sf=1.28 A=118.2 A=118.4 342 [94],[238],[317]
[302]: data by Joseph R. Bishop III, Bluffton, SC, USA
[30]: data by Dr.G.Hring, Rendsburg, Germany
These lens constants are offered only as a recommendation for a starting . [70]: data by HumanOptics AG, Germany
[73]: data by Dr.G.Felgemacher, Brilon, Germany
[307]: data by Prof.Dr.P.Rieck, Berlin, Germany
Rayner Superflex 620 H A=118.0 a0=1.20 a1=0.40 a2=0.10 pACD=5.39 sf=1.64 A=118.8 A=119.0 144 [81],[88]
Graefes Arch Clin Exp Ophthalmol. For information on lenses available in your region, contact your local Alcon surgical sales representative. [286]: data by Dr. Martin Drner, Bocholt, Germany
Hanita SEELENS A=118.6 a0=1.29 a1=0.40 a2=0.10 pACD=5.51 sf=1.73 A=118.9 A=119.2 51 [136]
. [235]: data by Th.Hofmann, Binningen, Switzerland
Zarracom Focusforce Basic F260 A=118.4 a0=1.55 a1=0.40 a2=0.10 pACD=5.68 sf=1.93 A=119.2 A=119.9 49 [347]